Pressure Testing Myths Busted

Pressure testing is a topic where a number of myths and misunderstandings have developed in the swimming pool industry. Below, we explain the truth behind 4 common misconceptions that should help you stay focused on efforts that will lead to leak detection success and profits.

MYTH #1: Pressure Testing is Unnecessary for Leak Detection

While you may be able to find common leaks without pressure testing, if you want to leave the pool assured that you have found all of the leaks . . . and you want to give the customer that assurance, pressure testing is critical.

There are other ways of finding easy to reach leaks in plumbing, but from the standpoint of conclusively determining if the entire line is leak free, nothing beats a properly performed pressure test.  Furthermore, despite advancements in cameras and other probes that have applications in some situations, the most common and dependable way of pinpointing leaks underground involves the use of a listening device that picks up the sound of pressurized air escaping from a leak into water saturated soil.

MYTH #2:  Air Can Be Used Interchangeably With Water for Pressure Testing

Air and water behave very differently in pressure testing situations.  Understanding three pressure testing principles that address these differences is important as you determine when to use air and when to use water to build pressure.

  1. Air compresses under pressure, water does not
  2. Air stays at the top of the pipe, water stays at the bottom
  3. Air escapes from leaks faster than water does

Our pressure testing slide show provides helpful diagrams and more explanation of how these principles affect your test results.  As a general rule it is best to use water when testing to determine if the line is leaking since it does not compress under pressure so it will show a loss in pressure quickly, even with a small loss in volume.  On the other hand, air trapped in a line can expand as water volume is lost from the leak, slowing (and sometimes completely masking) a drop in pressure. Additionally, if plugs happen to pop out under pressure they will come out with much less force if the line is pressurized with only water . . . trapped air will propel a popped plug like a cannon ball!

The main benefit of using air is that it makes a much better noise escaping from the pipe into water saturated soil than water does.  So, once you have identified a leaking section of plumbing with a water test, switch to air to produce a good noise that can be picked up by your listening device.

Myth #3: Air and Water Can Be “Mixed” in a Pressure Tester and Will Stay “Mixed” Inside the Pipe

We’ve debunked this myth by testing it on a plumbing system made of clear PVC.  Regardless of how they are transmitted into the pipe, water stays low and air stays high.  They do not stay mixed up just because they are put under pressure.  This is simple physics and anyone who says otherwise is selling you hocus-pocus.

Adding both air and water to a line is not the first step you should take when trying to make a good leak noise.  While it is indeed important for the soil to be full of water outside of the pipe where air will blow out through the leak, no noise is made unless air actually gets to the leak.  Since water stays at the bottom of the pipe and air at the top, if the leak is in the low end of the plumbing no air will get to it if you are adding both air and water.  So, all of the water above the leak level must be purged from the line before this happens. Generally this is best accomplished by removing a low plug and blowing air from the high end.  Once you see bubbles, replace the plug, set your air source regulator to maintain no higher than 5 psi, and begin listening.  Larger leaks and/or leaks in soil that drains quickly may necessitate adding water while air is going into the line.  To avoid noises inside the pipe, do this with a separate pressure tester from the low end of the plumbing.  The best results happen when air and water do not mix inside the plumbing . . . just at the leak!

MYTH #4: Certain Kinds of Gas Make Better Noises Than Others for Leak Location

Any gas escaping from a leak will make bubbling/gurgling /hissing/spotting sounds in the full range of sonic frequencies that can be picked up with a listening device.  Sometimes, leak detectors will use nitrogen tanks to deliver the gas into the line quietly (without the conflicting sound of a compressor).  However, these tanks are used not because of any special characteristic of the gas (in fact, the air we breathe is made up of 78% nitrogen) but because of its ease of availability and inexpensiveness in relation to other gasses.  SCUBA tanks adapted with an adjustable regulator can also be used if you can get them filled.  A small compressor works just fine for inducing air pressure, especially if you use a 50 foot hose that allows you  to position the compressor some distance from where you are listening.

In some situations where soil or leak conditions make it difficult to create a noise helium gas is used to find underground plumbing leaks.  In these situations a Helium Detector picks up the presence of the gas as it makes its way to the soil’s surface.  Helium is not being used because it makes a better noise, but because it can be detected by this detector.

If you have any questions about pressure testing or swimming pool leak detection, consult the Resource Center of our website or give us a call.


What makes a top notch listening device?

When it comes those tough underground plumbing leaks, electronic listening devices are the backbone of the leak detection industry.   While there are other methods the most reliable and consistent method is to make a noise at the leak with pressurized air escaping into water saturated soil, then listen for where the noise is coming from.  This noise can sometimes be picked up by just an open ear but often a listening device is needed to help amplify the sound and filter out other noises to focus in on leak sound and pinpoint location.

Choosing the right listening device for your company is an important decision. When researching a product purchase, similar to listening for a leak, there can be a lot of “noise” to sift through.  Here at Anderson Manufacturing we have combined research and testing with the experience of hundreds of pool leak detection professionals to find and keep the best option for a swimming pool leak listening device.

While there are many factors to think about such as cost, dependability and service after the sale. There are also some more technical criteria to consider when looking at purchasing a swimming pool leak listening device.   Since listening devices range from your standard geophones to sophisticated technology here are some tips for what criteria to look at.

Important criteria to consider when comparing listening devices:

Sensitivity – how well the device amplifies sounds from the transmitting material 

Frequency Range – how broadly the device can hear all the sounds created by a leak

Filtering – how effectively the device can filter out background noise enabling  you to focus on a leak sound

The Bigfoot microphone for the XLT30H reduces outside noise interference.
The Bigfoot microphone for the XLT30H reduces outside noise interference.
Sensitivity

The standard ground microphones that come with Fisher’s XLT17 and the XLT30H listening devices, use piezoelectric microphones because these are known to be the best type of microphone to use in situations where sounds are being picked up from liquids or solids.  Virtually every company that makes serious equipment for locating underground plumbing leaks for municipal work incorporates piezoelectric technology. Accessing the technological knowledge of those who have experience in this area is one reason we have chosen to work with Fisher and utilize their products.  This type of equipment requires more specialized expertise than standard microphone amplification (that used for music/voice etc.).

In practice you will find that sensitivity by itself however is not the only important performance criteria.  Most any device will be able to amplify a sound to the point that it will hurt your ears.  What’s more important is hearing the right sound and distinguishing it from background noise.  That’s where the other two important criteria come into play.

 

Frequency Range

Both pressurized underground plumbing leaks and static shell leaks in the pool make noises in a wide range of frequencies depending on a variety of conditions.   We like to think of the sounds a leak makes in the same way we do instruments in an orchestra.  You want to be able to hear everything from the shrillest piccolo to the deepest tuba.  Although every leak is different, as general rule underground plumbing leaks make sounds in the lower frequency ranges while static leaks in the shell of the pool are in the higher range.  If your listening device doesn’t pick up sounds at the top or bottom of this range you will be missing the fullness of the sound a leak makes or you may miss it altogether.  Both the Fisher XLT17 and XLT30H pick up sounds in a frequency range of 20Hz to 6000Hz.  In addition, the XLT30H includes a switch that enables the unit to work effectively both when sounds are in the low range (for underground leaks picked up by the Bigfoot microphone) and the higher ranges (for underwater leaks picked up by the hydrophone).

 

Filtering Capability

The final performance criteria, and what we consider to be the most important for swimming pool applications, is an area where Fisher devices particularly shine over all others we have researched.  A listening devices filter allows you to specifically highlight (or eliminate) a specific range of sounds.  Consider for instance that we only wanted to hear the violins in the orchestra of leak sounds we imagined above.  Filtering is important because the devices are so sensitive that we will likely hear other sounds around the pool (it always seems as though the next door neighbor want to mow their grass when you’re trying to find a leak!).  The filter helps us zero in on the leak sound without being distracted by the background noise.  Additionally, different ranges of sound behave differently underground or underwater.  Low frequency sounds travel much further than high frequency sounds.  By selecting high frequency sounds once a leak sound has been identified the frequency filter can help in pinpointing leaks to a small area.

 

Fisher devices provide a wide range of filtering options to address most any scenario. The Band Pass filter allows selection of a narrow band of frequency anywhere in the range of sound.  The Hi Pass filter focuses high frequency sounds providing adjustment of the low end of this range.  The Low Pass filter does the opposite – focusing on the low end and providing an adjustable high end..  The XLT30H also includes a Notch Filter that allows the elimination of a specific frequency range (for instance to minimize the “hum” of a nearby air-conditioner) and can be used at the same time as the other filters.

 

Another noise minimizing feature available on Fisher devices is especially important when the unit is used for listening to pipes in the ground.  The Bigfoot muffler utilized by Fisher to minimize outside noises transmitted through the air is the best we’ve seen.  This rubber boot deadens outside noises preventing them from reaching the sensitive piezoelectric microphone which makes direct contact with the pool deck or ground through a heavy aluminum foot.

 

Conclusion

Ultimately, we are convinced, that Fisher Listening Devices as sold by Anderson Manufacturing Co. are the most technologically advanced, well rounded tool for all types of swimming pool acoustical leak location   They have been continually improved through the years and currently represent the best package for addressing pool leak problems in both the plumbing and shell.  We back our belief with the evidence of thousands of successful customers and a satisfaction guarantee that promises your money back if you are not satisfied with their performance.

If you have made it this far through this you have taken in a lot of information, hopefully it has been helpful in making decisions that will affect your leak detection success.  Remember you can always call and talk through the buying process or for technical help regarding a leak or leak detection equipment. Thanks for reading!

 